Combined baby bathing/changing unit

Recall published
2006-12-25
Brand
Product title
Combined baby bathing/changing unit.
Product description
Category: Children’s equipment Product: Combined baby bathing/changing unit. Brand: PRENATAL Type/number of model: Reference 457817
Risk
This baby bathing/changing unit presents a serious risk of trapping various parts of a child's body and the risk of choking because: - there are holes which permit entry of the 5 mm gauge with a force of less than 30 N, but not of the 12 mm gauge; - there are holes which permit entry of the 25 mm gauge with a force of less than 30 N but do not permit entry of the 45 mm gauge; - the gap remaining between the changing table (when open) and the edge of the bath permits entry of the 45 mm gauge with a force of less than 30 N and does not permit entry of the 65 mm gauge; - the changing unit folds with a force of less than 200 N, with the consequent risk of injury to the child; - during the test the plastic button on the underside of the changing table became detached with a traction force of less than 90 N, producing a small part which could give rise to choking. This product does not comply with the relevant European standard EN 12221.
Measures taken
Measures ordered by public authorities: Withdrawal from the market ordered by the authority
Batch number / barcode
Model number
Recall type
Consumer product
Risk type
Injuries Suffocation
Country of origin
Italy
RAPEX Reference
0005/07
Risk level
Serious risk
Notifying country
Spain