Power supply units

Recall published
2007-03-12
Brand
  • Prescott
Product title
Power supply units
Product description
Risk
This product poses a risk of electric shock because - there is not sufficient electrical insulation between the primary circuit connected to the mains and the secondary circuit that can be touched. The secondary circuit can be touched via the product connected to the output of the power supply unit. In particular: - clearances/creepage distances in transformer T2 between the primary and the secondary windings are less than 4 mm/5 mm; a minimum of 0.2 mm between the primary winding and the output wires of the secondary winding and 0.5mm between the secondary winding and the output wires of the primary winding are measured; on the output wires there are not insulation tubes; - clearances/creepage distances in transformer T3 between the primary and the secondary windings are less than 4 mm/5 mm; a minimum of 0.3 mm between the primary winding and the output wires of the secondary winding and 0.3 mm between the secondary winding and the output wires of the primary winding are measured; on the output wires there are not insulation tubes. This product does not comply with the Low Voltage Directive and the relevant European standard EN 60950.
Measures taken
Measures ordered by public authorities: Recall from consumers ordered by the authorities
Batch number / barcode
Model number
LC-D500EXP
Recall type
Consumer product
Risk type
Electric shock
Country of origin
Unknown
RAPEX Reference
0271/07
Risk level
Serious risk
Notifying country
Finland